top bar

Difference between revisions of "ZeissCAN"

(Zeiss CAN adapter)
Line 8: Line 8:
 
<tr><td valign="top">'''Devices:'''</td><td>Scope, Shutter (external and internal), Reflectorturret, SideportTurret, ObjectiveTurret, Excitation Lamp Switcher, Halogenlamp, Z-drive</td></tr>
 
<tr><td valign="top">'''Devices:'''</td><td>Scope, Shutter (external and internal), Reflectorturret, SideportTurret, ObjectiveTurret, Excitation Lamp Switcher, Halogenlamp, Z-drive</td></tr>
 
<tr><td width=20%>'''Serial Port settings:'''</td><td>9600 baud, 1 stop bit, 2000 ms answertime out, 0 ms delaybetweenCharsMs, Handshaking none.</td></tr>
 
<tr><td width=20%>'''Serial Port settings:'''</td><td>9600 baud, 1 stop bit, 2000 ms answertime out, 0 ms delaybetweenCharsMs, Handshaking none.</td></tr>
 +
 +
<tr><td><b>Automated Serial Port Setup:</b></td><td>Yes</td></tr>
 +
 +
<tr><td><b>Peripheral device discovery:</b></td><td>Supported</td></tr>
 +
 
</table>
 
</table>
  

Revision as of 14:02, 22 April 2011

Zeiss CAN adapter

Summary:Controls Zeiss microscopes that use the CAN protocol (Axiovert 100m, Axiovert200m, Axioplan2, Axioplan2+)
Author:Nico Stuurman
License:LGPL
Platforms:Windows, Mac OS X and linux (serial port)
Devices:Scope, Shutter (external and internal), Reflectorturret, SideportTurret, ObjectiveTurret, Excitation Lamp Switcher, Halogenlamp, Z-drive
Serial Port settings:9600 baud, 1 stop bit, 2000 ms answertime out, 0 ms delaybetweenCharsMs, Handshaking none.
Automated Serial Port Setup:Yes
Peripheral device discovery:Supported


This adapter controls Zeiss microscopes that use the (older) CAN bus interface, but does not control the newer Zeiss microscopes (like the AxioObserver) that use the ZeissCAN29 protocol. The adapter directly communicates to the microscope through the serial port (i.e., it does not use the MTB library provided by Zeiss) and therefore works on all platforms. No additional software is needed. You will need to define all hardware that is part of your microscope in the Hardware Configuration Wizard (i.e., Micro-Manager does not query the microscope itself and it also does not use the information you might have entered in the Axioset program). In any case, you will need to define the 'ZeissScope' device as this tells to which serial port the scope is attached. Serial port settings are: 9600 baud, 1 stop bit, 2000 ms answertime out, 0 ms delaybetweenCharsMs. For Handshaking, first try 'None' and if that does not work try 'Hardware'.

For older microscopes that have the 'MF' firmware instead of the newer 'ZM' firmware (the firmware version will be a property of the Zeisscope device, in general, the AxioPlan 2 and Axiovert 100m have the MF firmware and the AxioPlan2+ and Axiovert200m have the ZM firmware) use the ZeissShutterMFFirmware instead of the ZeissShutter. There are three types of the ZeissShutterMFFirmware shutter: 1 = incident light, 2= condenser front lens, 3 = external motorized Mirror with two lamps. Note that with the ZM firmware the external motorized mirror is a different device (Excitation Lamp Switcher).

--Nico 17:23, 8 September 2007 (PDT)