top bar

Difference between revisions of "OlympusIX81"

(Olympus IX81/ BX61 adapter)
 
(8 intermediate revisions by 2 users not shown)
Line 1: Line 1:
== Olympus IX81 adapter ==
+
== Olympus IX81/ BX61 adapter ==
  
<table><tr><td>
+
<table cellspacing=3><tr><td>
'''Summary:'''</td><td valign="top">Controls Olympus IX81 microscope</td></tr>
+
'''Summary:'''</td><td valign="top">Controls Olympus IX81/ BX61 microscope</td></tr>
<tr><td>'''Author:'''</td><td>Jeff Kuhn and Arthur Edelstein</td></tr>
+
<tr><td>'''Author:'''</td><td>Jeff Kuhn and Arthur Edelstein, BX61 support added by Shalin Mehta</td></tr>
 
<tr><td>'''License:'''</td><td>not Open Source</td></tr>  
 
<tr><td>'''License:'''</td><td>not Open Source</td></tr>  
 
<tr><td>'''Platforms:'''</td><td>Windows, Mac OS X (through serial port)</td></tr>
 
<tr><td>'''Platforms:'''</td><td>Windows, Mac OS X (through serial port)</td></tr>
Line 10: Line 10:
 
<tr><td valign=top>'''Default serial port settings:'''</td><td valign=top>
 
<tr><td valign=top>'''Default serial port settings:'''</td><td valign=top>
  
{|
+
{| cellspacing="2" border="0" cellpadding=3
 +
|-AnswerTimeout||500
 
|-
 
|-
|Baud rate:||19200
+
|BaudRate||19200
 
|-
 
|-
|Parity:||Even
+
|DelayBetweenCharsMs||0
 
|-
 
|-
|Stop bits:||2
+
|Handshaking||Off
 +
|-
 +
|Parity||Even
 +
|-
 +
|StopBits||2
 
|}
 
|}
  
Line 22: Line 27:
 
</tr>
 
</tr>
 
</table>
 
</table>
 +
<br>
 +
These serial port settings require all DIP switches on the front of the "Frame Control Unit" (the box connected to the serial cable) to be in their default position: off (zero).
 +
 +
BX61 specific notes: Currently only one filter wheel is supported (connected to FW1 port on the controller).
 +
 +
 +
{{Devices_Sidebar}}

Latest revision as of 09:58, 10 May 2011

Olympus IX81/ BX61 adapter

Summary:Controls Olympus IX81/ BX61 microscope
Author:Jeff Kuhn and Arthur Edelstein, BX61 support added by Shalin Mehta
License:not Open Source
Platforms:Windows, Mac OS X (through serial port)
Available since version:1.3.22
Default serial port settings:
BaudRate 19200
DelayBetweenCharsMs 0
Handshaking Off
Parity Even
StopBits 2


These serial port settings require all DIP switches on the front of the "Frame Control Unit" (the box connected to the serial cable) to be in their default position: off (zero).

BX61 specific notes: Currently only one filter wheel is supported (connected to FW1 port on the controller).


© Micro-Manager : Vale Lab, UCSF 2006-2011 | All Rights Reserved | Contact